Inclined Elevator

Inclined Elevator

Based on the working condition, the operating principles of the inclined elevator are diverse, which is mainly to tract the car by the traction, force driving, gear and teeth and rope climbing etc, and the traction angle is operating in the scope of 0°<α<90° theoretically. The passenger can feel comfortable and convenient like taking the regular elevator. The angle can be changed if there is special need, and this kind of elevator is mainly applied for the special demands of the bridge, chimney, dam, resort's slope and military etc.

Introduction

Unique signal acquisition/span>

By using the unique double line carrier transmission mode, the command signal of the car is connected with the control of the system reliably, which avoids the disadvantages of the multi angle angle transmission which is usually used in the oblique elevator. The signal transmission is reliable, the failure rate is low, the maintenance is free, and the well path signal adopts the bus four wire serial transmission mode.

Intelligent door machine

Keep track of the running track of the intelligent elevator door machine, thereby changing the relative position of the elevator door knife, ensure the reliable connection and the stop door knife gateball layer.

Car signal control

The battery powered by DC high performance maintenance, control integration door machine, and the barge stop seat type automatic charging way to supplement the energy of the battery, the whole car, only two safety loop connection cable and control system (with standard regulations), car lighting and ventilation are use the battery power supply, emergency call also uses audio carrier technology to achieve.

Parameter Table

Rated load Drag method Rated speed Net dimension of car Dimension of door opening Dimension of hoistway Dimension of machine room Over head Pit depth
Width Depth Width Height Width Depth Width Depth Height
kg m/s A B E F C D R T H Q P
Rated load Drag method Rated speed Net dimension of car Dimension of door opening Dimension of hoistway Dimension of machine room Over head Pit depth
Width Depth Width Height Width Depth Width Depth Height
kg  

V

V

V

F

m/s A B E F C D R T H Q P
1000 0.5/1.0 1500 1800 1300 2100 2400 2100 3500 3500 2600 4300 1400
1600 0.5 2000 2000 1500 2200 2800 2350 3500 4000 2600 4400 1400
2000 0.5 2000 2400 1600 2200 2950 2750 3500 4500 2600 4500 1400
3000 0.5 2500 2600 2000 2200 3600 2950 4300 4700 2800 4500 1400
5000 0.25/0.5 3000 3300 2600 2400 4450 3650 5500 5500 2800 4800 1500/1600

Details PC version

Standard Function

Standard Function Function Description
>Brake detection and protection Open and closed through real-time monitoring of the brake brake arm detection switch. When the brake is not required when opened. The system will not allow the elevator.
>The correction speed and the number of floors of station The system in operation is detected in the end station after the switch. The elevator will force the speed and automatic correction of floor display.
>Limit protector The system detects the limit switch action, will immediately stop the elevator running.
>Maximum protection The system detects the limit switch action, the whole system will immediately power down.
>Overspeed protection When the elevator up and down more than 1.2 times the rated speed, cut off the control power supply, the elevator will stop running.
>Layer station floor, direction display The station shows the elevator floor and the direction to be run.